BCS Laboratories
An independent lab in Gainesville, Florida, accredited to ISO/IEC 17025:2017 (certificate L2422, through ANAB). It also holds Florida DOH E82924, EPA FL01147 and PA DEP 68-03950.
A filter company's word is not enough, so here is who ran the test, how they ran it and what they measured for each contaminant. The full lab report is linked on this page.

An independent, accredited lab tested the large three-stage town-water Pure Way system between March and May 2026. Under laboratory challenge conditions it reduced chlorine by more than 99.1%, chloramine by more than 99.6%, total trihalomethanes by 99.93%, haloacetic acids by more than 98.7%, six PFAS by more than 99.3% and lead by more than 99.92%.
Those are initial-performance figures from water carrying far more of each contaminant than a home tap, and they are not a guarantee for any home.
An independent lab in Gainesville, Florida, accredited to ISO/IEC 17025:2017 (certificate L2422, through ANAB). It also holds Florida DOH E82924, EPA FL01147 and PA DEP 68-03950.
Ran the PFAS tests (EPA method 533) and the haloacetic acid tests (EPA method 552.3).
Ran the pharmaceutical and personal care product panel.
Each row is one contaminant fed into the system at a level far above a real tap, and what was left afterward. The thin bar under each name shows how much remained.
| What was tested | Fed in | What was left | Reduction | Method |
|---|---|---|---|---|
| Disinfection and its byproducts | ||||
| Chlorine | 2.2 mg/L | 0.02 mg/L | 99.1% | SM 4500-Cl G |
| Chloramine | 3.1 mg/L | 0.01 to 0.02 mg/L | 99.6% | SM 4500-Cl G |
| Total trihalomethanes | 490 ppb | 0.33 to 0.35 ppb | 99.93% | EPA 524.3 |
| Haloacetic acidsHAA5 and HAA9, nine species | 210 ppb | Under 2.8 ppb | >98.7% | EPA 552.3, Pace |
| Industrial and organic | ||||
| Volatile organicsMeasured as chloroform | 280 ppb | 0.12 to 0.22 ppb | 99.92% | EPA 524.3 |
| PFAS, six speciesPFOA, PFOS, PFHxS, PFHpA, PFBS and PFDA | 0.52 ppb total | Under 0.0039 ppb | >99.3% | EPA 533, Pace |
| Pharmaceuticals and personal care products | 72 ppb (panel) | Under 0.52 ppb | >99.3% | Eurofins |
| Metals | ||||
| Lead | 130 ppb | Under 0.1 ppb | >99.92% | EPA 200.8 (ICP-MS) |
| Particles | ||||
| Microplastics0.5 to 1.0 micron | 3,500,000 particles/mL | 3,700 to 4,500 per mL | 99.9% | Particle count |
Third-party laboratory testing by BCS Laboratories, Inc. (ISO/IEC 17025:2017, certificate L2422), March to May 2026, on the large 4.5 by 20 inch three-stage town-water system under laboratory challenge conditions at a 100-gallon test point. Results represent initial filtration performance and are not a guarantee of performance in any individual home. Pure Way Eastern Shore installs this same 4.5 by 20 inch size. Read the full lab report.
Select components of the system are certified by IAPMO R&T. NSF/ANSI 42 covers chlorine taste and odor, NSF/ANSI 61 covers drinking water system components, and NSF/ANSI 372 covers lead-free materials. The certificates are dated April 20, 2026 and apply to the large town-water whole-house system. Pure Way is not the certification holder, and the listings are public at pld.iapmo.org.
Only those three claims carry a certification. Everything else in the table above is laboratory-verified, which means a laboratory measured it and we are showing you the numbers.
Aesthetic effects: chlorine taste and odor
IAPMO R&T certificate of listing, file WP-30743. Effective April 2026, void after April 2031.
Drinking water system components: health effects
IAPMO R&T certificate of listing, file WP-30744. Effective April 2026, void after April 2031.
Lead-free requirements
IAPMO R&T certificate of listing, file WP-30745. Effective April 2026, void after April 2031.
The certificates are issued to Pure Way Filtration and apply to the large 4.5 by 20 inch town-water whole-house system. A certificate is not evidence of current listing, so check the status at pld.iapmo.org.
The water fed in carried far more of each contaminant than a home tap does. It was measured at a 100-gallon test point, early in the filter's rated life, and the lab's own report says the results may not represent a real-life process. The testing followed the lab's own procedures to ISO/IEC 17025, not NSF/ANSI protocols. No laboratory test predicts what happens in a particular house. The free test at your own tap measures your own water.
The first report holds every result in the table above except microplastics. The second holds the microplastics result and the lab's separate virus, bacteria and cyst tests, which this page does not cite.
Pure Shield, Nano Armor and Chem Guard, in order, with no salt, no electricity and no drain line. See the system.
Read what your own water utility reported, each result against its legal limit. Look up your town.
We test at your kitchen tap and explain the readings, at no cost and no obligation. Book a free water test.
Tanks, cartridges and long lists of contaminants all start to sound alike. These questions cut through it, and you can put them to us too.
We test the water at your tap, in your home, at no cost. Tell us where you are and what kind of water you have, and we will call you to set a time. No obligation.
Rather talk now? Call (410) 431-0822.
BCS Laboratories, Inc. of Gainesville, Florida ran the test. It is accredited to ISO/IEC 17025:2017 (certificate L2422 through ANAB). Pace Analytical ran the PFAS and haloacetic acid tests, and Eurofins ran the pharmaceutical panel. The testing was done between March and May 2026.
The full lab reports are linked on this page, under the results table. One covers the chemical, organic and lead results, and a second covers microplastics and the microbial tests. Each names the methods used and shows the result for each test.
The large three-stage town-water system, 4.5 by 20 inch, under laboratory challenge conditions at a 100-gallon test point. Pure Way Eastern Shore installs this same size.
No. The test fed in far more of each contaminant than any home tap carries, and it measured early in the filter's life. No laboratory test predicts what happens in a particular house, which is why the free water test measures your own water.
Select components are certified by IAPMO R&T to NSF/ANSI 42 (chlorine taste and odor), 61 (drinking water system components) and 372 (lead-free materials). Pure Way is not the certification holder. The certifications cover those three claims, and everything else in the table is laboratory-verified, not certified.
No. It is not a true softener, and on town water it does not remove sodium, fluoride, iron, manganese, nitrate or arsenic. We have add-ons that take care of any of those, so ask at the free water test.